Factory wholesale Mini Digital Incubator - Egg Incubator HHD EW-24 for home use hatcher – Edward
Factory wholesale Mini Digital Incubator - Egg Incubator HHD EW-24 for home use hatcher – Edward Detail:
Features
【Transparent cover】Never miss a hatching moment and support to observe 360°
【One button LED tester 】Easily check the eggs development
【3 in 1 combination】Setter,hatcher,brooder combined
【Universal egg tray】Suitable for chick,duck,quail,birds eggs
【Automatic egg turning】Reduce workload,no need to wake-up at midnight.
【Overflow holes equipped】Never worry about too much water
【Touchable control panel】Easy operation with simple button
Application
EW-24 eggs incubator is equipped with universal egg tray,able to hatch chick, duck, quail,bird,pigeon eggs etc by kids or family.It helped to enhance parent-child relationship greatly and enlighten science and education.
Products parameters
Brand | HHD |
Origin | China |
Model | EW-24/EW-24S |
Material | ABS&PET |
Voltage | 220V/110V |
Power | 60W |
N.W. | EW-24:1.725KGS EW-24S:1.908KGS |
G.W. | EW-24:2.116KGS EW-24S:2.305KGS |
Packing Size | 29*17*44(CM) |
Warm tip | Only EW-24S enjoys One button LED tester function,and different in control panel design. |
More details
Feel free to hatch chick,duck,quail,bird,pigeon and parrot—whatever fits by equipped universal egg tray.Various eggs can hatch in one machine.
The whole hatching process can be finished in this 3-in-1 combined machine ,very convenient and cost-effective.
Detailed machine descriptions to give you a better understanding of the product.
Transparency cover allows for convenient at-a-glance monitoring,and water filling hole avoid opening lid frequently to affect the stability of temperature and humidity.
Two fans (thermal cycling) provides more reasonable heater cycle system, circulating air ducts for more stable temperature and humidity inside the machine.
Simple control panel is easy to operate,and easy to add water.it enjoys automatic egg turning and security concealed power outlet.
Strong cardboard packaging with foam wrapped around the machine to reduce damage to the product from knocks in transit.
Incubator Operation
Ⅰ. Setting Temperature
The incubator temperature is set at 38°C(100°F) before shipment. User can adjust temperature according to the egg category and local climate. If the incubator can’t reach 38°C(100°F) after working for several hours,
please check: ①The setting temperature is above 38°C(100°F) ②The fan is not broken ③The cover is closed ④The room temperature is above 18°C(64.4°F).
1. Press button “Set”once.
2. Press button“+”or“-”to set required temperature.
3. Press button“Set”to exit setting process.
Ⅱ Setting Temperature Alarm Value (AL & AH)
The alarm value for high and low temperature is set at 1°C(33.8°F) before shipment.
For low temperature alarm(AL):
1. Press button “SET” for 3 seconds.
2. Press button“+”or“-”until“AL”is illustrated on the temperature display.
3. Press button“Set”.
4. Press button“+”or“-”to set required temperature alarm value.
For high temperature alarm(AH):
1. Press button “Set” for 3 seconds.
2. Press button“+”or“-”until“AH”is illustrated on the temperature display.
3. Press button“Set”.
4. Press button“+”or“-”to set required temperature alarm value.
Ⅲ Setting Upper & Lower Temperature Limits (HS & LS)
For example, if the upper limit is set at 38.2°C(100.8°F) while lower limit is set at 37.4°C(99.3°F), the incubator temperature can only be adjusted within this range.
Ⅳ. Low Humidity Alarm (AS)
The humidity is set at 60% before shipment. User can adjust low humidity alarm according to the egg category and local climate.
1. Press button “Set” for 3 seconds.
2. Press button“+”or“-”until“AS”is illustrated on the temperature display.
3. Press button“Set”.
4. Press button“+”or“-”to set low humidity alarm value.
The product will make alarm calls at low temperature or humidity. Re-set the temperature or add water will solve this problem.
Ⅴ.Calibrating the Temperature Transmitter(CA)
The thermometer is set at 0°C(32°F) before shipment. If it illustrates a wrong value, you should put a calibrated thermometer into the incubator and watch for the temperature differentials between calibrated thermometer and controller.
1. Calibrate the the transmitter dimension.(CA)
2. Press button “Set” for 3 seconds.
3. Press button“+”or“-”until“CA”is illustrated on the temperature display.
4. Press button“Set”.
5. Press button“+”or“-”to set required dimension.
Product detail pictures:
Related Product Guide:
To be a result of ours specialty and service consciousness, our company has won a superb reputation between customers all around the environment for Factory wholesale Mini Digital Incubator - Egg Incubator HHD EW-24 for home use hatcher – Edward , The product will supply to all over the world, such as: Morocco, Irish, Lithuania, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we'll continue to develop, to supply the high-quality goods and services, and promote lasting cooperation with our customers, common development and create a better future.